Kardex VCA, KVCA, Vertical Carousel, wCARMAN, storage units, high density storage, stock storage

Product Support

wCARMAN 32

Manuals
Below are links to allow you to download the current manual for the wCARMAN 32 software application.

Revision History
Below is an outline of the latest new features added to the wCARMAN 32 software and in what version it was introduced.

Version Details
1.6.23.20090922 Current Version of wCARMAN 32
1.6.02.20090331 Added support for graphical labels. Any Windows-based can now theoretically be supported.
1.5.82.20080910 Find Run Point - Added support for passing back Part, Lot and Expiry date to the Place form.
1.5.78.20080701 Lot Number - Added a hidden Lot Number field that is displayed when picking and verifying. It displays the Lot Number of the current location so allowing users to type in a part number and display the lot you are picking.
1.5.71.20080414 SetShelfForm - Added in text to display which machines shelf is being set/moved.
1.5.68.20080318 Multiple Machines - Added support for demo mode control of multiple "machines".
1.5.56.20071019 Database - Added new field to Location table, LocType.
1.5.55.20071017 Scale - Added support for Rinstrum K402scales.
1.5.53.20070927 Find Form - Added section to check current quantity.
1.5.47.20070307 MainForm - All machines can now connect simultaneously.
1.5.42.20061220 Verify - Added interupt capabilities to Zero Location Verify. Added optional Zero Quantity locations only, instead of all empty locations.
1.5.41.20061121 Global Verify - Added functionality to ignore new locations while a global verify is still in progress. Is only available if "Reset Verified Locations" is OFF also.
1.5.40.20061102 Msg Passing - Added new support for passing msg from one form to another. Currently run points were used and these were limited. Msg passing allows one plugin to effectively control another plagin and vice-versa.
1.5.36.20060901 Panasonic PLC - A new PLC type (Panasonic) has been added to the available PLC types.
1.5.29.20060609 T3 Comm. DLL - Added config. options to set the amount of digits in the message sent to the machine. It uses the same code as the T3 Net Server now.
1.5.29.20060609 Added Tare weight support. You can now set a single tare container weight on the Peripherals tab in Configeration. Only used in placing mode.
1.5.27.20060518 Default Location - A new field, DefaultMachine has been added to the part table. This will be populated when an item is first placed.
1.5.08.20050620 Reports - Added optional headers when outputting files, check box on the Reporting tab in Config. New report added, Reorder Min/Max. Reorder 2 report removed, option was added to output the TotalQty in the Reorder report.
1.5.00.20020322 Added Interrupt Uncompleted Lists so a list can be resumed when more stock or the part numbers are available. Added Quick List feature for quickly doing local lists.
1.5.00.20020315 Added a skip button for placing to the Get Quantity dialog


Copyright © 2002-2009 Kardex VCA Pty. Ltd. All rights reserved.